- Zinc Oxide Eugenol sealer based on Grossman’s formula
- Long working time & excellent lubricating properties
- Non-staining & non-irritating
PACKAGING
- Automix Mix Kit: 1 x 15g Cartridge (Base / Catalyst), 20 x Auto Mix Tips, 1 x Instruction Manual.
₹750.00
Technical Data | Standard Applied | |
---|---|---|
1. Mixing Time | 30 Sec. | ISO 6876 |
2. Working Time | 30 Min. | |
3. Setting Time | 45 – 60 Min. | |
4. Flow | 17 mm | |
5. Solubility | > 2% | |
6. Film Thickness | 45 μm |
Instructions for Use :
The root canal should be thoroughly dry before filling, over filling root canals should be avoided. Both glass slabs and spatula should be sterilized and thoroughly dry prior to use for mixing cement. Place 1 scoop of powder and 4-5 drops of liquid ( P:L-1:2) on the glass slab. Spatulate small portions of the powder into liquid until all particles of powder are dissolved. Gradually add more portions of powder to the mix, spatulating thoroughly for 2:00-2:30 (min :sec) until a very smooth creamy paste is obtained. Working time is 30 minutes. Introduce the paste into the prepared root canal with a root explorer. Insert the Gutta Percha and seal the coronal end with base sealer. Net setting time is 45-60 minutes from the start of the mix. The dispensed material shall not be placed back in the container and the dose once applied and used will not be reused.
Warnings : Avoid prolonged or repeated contact with skin (allergic contact dermatitis), and eyes. Avoid prolonged inhalation. Do not take it internally. Contact with the skin may cause irritation, burns or hypersensitivity. If contact with skin occurs immediately wipe off thoroughly with cotton and alcohol and then wash well with soap and water. If skin rash and sensitization or other allergic reaction occurs discontinue use and seek medical attention. If the product comes into contact with the eyes, rinse thoroughly with fresh water and consult a physician. It should not be used with patients who have a history of severe allergic reaction to any of the components.
Precautions :
Contraindications : Do not use Zical with patients that have a history of allergic reaction to Iodine compounds. Avoid contact with eyes.
Storage Conditions : Store at temperature between 10°C(50°F) to 24°C(75°F). Close the cap carefully after use. Keep away from moisture. Shelf life is not affected after opening if stored in a cool dry place.
Shelf Life : 3 years from the date of manufacturing.
Reviews